• Firewall Throughput
  • ۴.۵ Gbps



  • IPS Throughput
  • ۴۰۰ Mbps



  • NGFW Throughput
  • ۲۵۰ Mbps



  • Threat Protection Throughput
  • ۲۰۰ Mbps



  • Application Control Throughput
  • ۶۵۰ Mbps



  • IPsec VPN Throughput
  • ۲ Gbps



  • SSL-VPN Throughput
  • ۱۵۰ Mbps



  • Firewall Latency
  • ۳ μs



  • Concurrent Sessions (TCP)
  • ۱.۳ Million



  • New Sessions/Second (TCP)
  • ۳۰,۰۰۰



  • Interface
  • Multiple GE RJ45 | WiFi variants | Variants with internal storage | Variants with PoE/+ interfaces



  • Local Storages




  • company
  • Fortinet
    Fortinet
    f5
    f5
  • AC Power Supply
  • ۱۰۰–۲۴۰V AC, 50–۶۰ Hz
    ۱۰۰-۲۴۰V AC, 50–۶۰ Hz, 11.5 Amp Maximum


  • Form Factor
  • Desktop
    ۳RU Rackmount


  • Virtual Domains (Default / Maximum)
  • ۱۰ / ۱۰



  • GB/Day of Logs

  • ۳۰۰۰


  • Analytic Sustained Rate (logs/sec)

  • ۴۲,۰۰۰


  • Collector Sustained Rate (logs/sec)

  • ۶۰,۰۰۰


  • Devices/VDOMs (Maximum)

  • ۴۰۰۰


  • Max Number of Days Analytics

  • ۳۰


  • FortiGuard Indicator of Compromise (IOC)

  • Yes


  • Total Interfaces

  • +۴x GE, 2x SFP


  • Storage Capacity

  • ۴۸TB (16 x 3 TB – ۴۸ TB max)


  • Usable Storage (After RAID)

  • ۴۲TB


  • Removable Hard Drives

  • Yes


  • RAID Levels Supported

  • RAID 0/1/5/6/10/50/60


  • RAID Type

  • Hardware / Hot Swappable


  • Default RAID Level

  • ۵۰


  • Redundant Hot Swap Power Supplies

  • Yes


  • Height x Width x Length (cm)

  • ۱۳.۲x 43.7 x 64.8


  • Power Consumption (Average / Maximum)

  • ۴۴۹W / 541W for 12 HDD


  • Heat Dissipation

  • ۱۸۴۶.۵BTU/h


  • Safety Certifications

  • FCC Part 15 Class A, C-Tick, VCCI, CE, UL/cUL, CB


  • Intelligent Traffic Processing


  • L7 requests per second: 3M L4 connections per second: 1.1M L4 HTTP requests per second: 14M Maximum L4 concurrent connections: 80M Throughput: 80 Gbps/40 Gbps

  • Hardware Offload SSL/TLS


  • ECC†: ۲۵K TPS (ECDSA P-256) RSA: 40K TPS (2K keys) ۲۰ Gbps bulk encryption

  • FIPS SSL


  • N/A

  • Hardware Compression


  • ۲۰ Gbps

  • Hardware DDoS Protection


  • ۷۰M SYN cookies per second

  • TurboFlex Performance Profiles


  • Tier 3

  • Software Compression


  • N/A

  • Software Architecture


  • ۶۴-bit TMOS

  • On-Demand Upgradable


  • N/A

  • Virtualization (Maximum Number of vCMP Guests)


  • ۱۲

  • Processor


  • One 6-Core Intel Xeon processor (total 12 hyperthreaded logical processor cores)

  • Memory


  • ۹۶ GB DDR4

  • Hard Drive


  • ۱x 480 GB Enterprise Class SSD Model with Dual SSDs in RAID 1 also available

  • Gigabit Ethernet CU Ports


  • Optional SFP

  • Gigabit Fiber Ports (SFP)


  • Optional SFP+ (SX or LX)

  • ۱۰ Gigabit Fiber Ports (SFP+)


  • ۸ SR/LR (sold separately); optional 10G copper direct attach

  • ۴۰ Gigabit Fiber Ports (QSFP+)


  • ۴ SR4/LR4 (sold separately) (QSFP+ optical breakout cable assemblies available to convert to 10G ports)

  • Power Supply


  • ۲x 650W Platinum AC PSU (2x 650W DC PSU Option)
    One to four 90 VAC (1200W) to 240 VAC (2000W) auto ranging20A per input line (max)DC power (option)One to four 1200W -36 to -72 VDC10 to 40A maximum per supply Note: Please refer to the Platform Guide: VIPRION 4400on askf5.com for the latest specific AC power ratings.
  • Typical Consumption


  • ۳۱۰W (dual power supply, 110V input)

  • Input Voltage


  • ۱۰۰-۲۴۰ VAC +/- 10% auto switching, 50/60hz

  • Typical Heat Output


  • ۱۰۶۰ BTU/hour (dual power supply, 110V input)

  • Dimensions


  • ۱.۷۲” (۴.۳۷ cm) H x 17.4” (۴۴.۲ cm) W x 30.6” (۷۷.۷۲ cm) D ۱U industry standard rack-mount chassis
    ۱۲.۲”(۳۰.۹ cm)Hx17.4”(۴۴.۲ cm)Wx21”(۵۳.۳ cm)D7U industry standard rack-mount chassis
  • Weight


  • ۳۰ lbs. (13.6 kg) (dual power supply)
    ۸۷lbs.(39.5 kg)(4power supplies, 1fan trays,3blanks)
  • Operating Temperature


  • ۳۲° to 104° F (0° to 40° C)
    ۳۲°to 104° F (0° to 40° C)
  • Operational Relative Humidity


  • ۵% to 85% at 40° C

  • Safety Agency Approval


  • ANSI/UL 60950-1-2014 CSA 60950-1-07, including A1:2011+A2:2014 IEC 60950-1:2005, A1:2009+A2:2013 EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013
    UL60950 (UL1950-3) CSA-C22.2 No. 60950-00(bi-national standard with UL 60950) CB test certification to IEC 950 EN 60950
  • Certifications/ Susceptibility Standards


  • ETSI EN 300 386 V1.6.1 (2012) EN 55032:2012 Class A; EN 61000-3-2:2014 EN 61000-3-3:2013; EN 55024:2010 FCC Class A (Part 15), IC Class A, VCCI Class A
    EN55022 1998 Class A EN55024 1998 Class A FCC Part 15B Class A VCCI Class A NEBS Certified
  • Relative Humidity



  • ۵to 85% at 104° F (40° C)
  • Certifications/Susceptibility Standards


  • ETSI EN 300 386 V1.6.1 (2012) EN 55032:2012 Class A; EN 61000-3-2:2014 EN 61000-3-3:2013; EN 55024:2010 FCC Class A (Part 15), IC Class A, VCCI Class A
    EN55022 1998 Class A EN55024 1998 Class A FCC Part 15B Class A VCCI Class A NEBS Certified
محصولی برای مقایسه وجود ندارد.