company
juniper
f5
f5
Intelligent Traffic Processing
L7 requests per second: 2M
L4 connections per second: 800K
L4 HTTP requests per second: 7M
Maximum L4 concurrent connections: 40M
Throughput: 60 Gbps/35 Gbps L4/L7
Hardware Offload SSL/TLS
ECC†: ۲۰K TPS (ECDSA P-256)
RSA: 35K TPS (2K keys)
۲۰ Gbps bulk encryption
FIPS SSL
۸k TPS (FIPS 140-2 Level 3)
Hardware Compression
۲۰ Gbps
Hardware DDoS Protection
۵۰M SYN cookies per second
TurboFlex Performance Profiles
Tier 3
Software Compression
N/A
Software Architecture
۶۴-bit TMOS
On-Demand Upgradable
N/A
Virtualization (Maximum Number of vCMP Guests)
۸
Processor
One 4-Core Intel Xeon processor (total 8 hyperthreaded
logical processing cores)
Memory
۴۸ GB DDR4
Hard Drive
Dual SSD 2x 480GB Enterprise Class SSD
Gigabit Ethernet CU Ports
Optional SFP
Gigabit Fiber Ports (SFP)
Optional SFP+ (SX or LX)
۱۰ Gigabit Fiber Ports (SFP+)
۸ SR or LR (sold separately);
Optional 10G copper direct attach
۴۰ Gigabit Fiber Ports (QSFP+)
۴ SR4/LR4 (sold separately) (QSFP+ optical breakout cable
assemblies available to convert to 10G ports)
Power Supply
۱x 650W Platinum AC PSU (Additional PSU optional, 2x 650W
DC PSU Option)
AC power supply
One to two 100-240 VAC (800W)
۵۰/۶۰ Hz auto ranging
۱۰A per input line (max)
DC power supply (option)
Typical Consumption
۲۶۵W (single power supply, 110V input)
Input Voltage
۱۰۰-۲۴۰ VAC +/- 10% auto switching, 50/60hz
Typical Heat Output
۱۲۱۵ BTU/hour (single power supply, 110V input)
Dimensions
۱.۷۲” (۴.۳۷ cm) H x 17.4” (۴۴.۲ cm) W x 30.6” (۷۷.۷۲ cm) D
۱U industry standard rack-mount chassis
۳.۴”(۸.۶ cm)H x 17.3”(۴۴.۰ cm) W x 24.5” (۶۲.۲ cm) D
۲U industry standard rack-mount chassis
Weight
۲۶ lbs. (11.8 kg) (dual power supply)
۳۱.0lbs.(14.1 kg)(1 blank line card, 0 power supplies, 0 blades, 1 fan tray)
Operating Temperature
۳۲° to 104° F (0° to 40° C)
۳۲°to 104° F (0° to 40° C)
Operational Relative Humidity
۵% to 85% at 40° C
Safety Agency Approval
ANSI/UL 60950-1-2014
CSA 60950-1-07, including A1:2011+A2:2014
IEC 60950-1:2005, A1:2009+A2:2013
EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013
EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011
IEC 60950-1:2005, A1:2009
CSA 60950-1-07, Including Amendment 1:2011
ANSI/UL 60950-1-2011
Evaluated to all CB Countries
Certifications/ Susceptibility Standards
ETSI EN 300 386 V1.6.1 (2012); EN 55032:2012/AC:2013
EN 61000-3-2:2014; EN 61000-3-3:2013; EN 55024:2010;
FCC Class A (Part 15), IC Class A; VCCI Class A
FCC Part 15 Class A
VCCI Class A
ETSI EN 300 386 V1.5.1 (2010)
EN 55022:2010 Class A
EN 61000-3-2:2006 A1:2009+A2:2009
EN 61000-3-3:2008
EN 55024:2010
EN 55022:2010 Class A
EN 61000-3-2:2006 A1:2009+A2:2009
EN 61000-3-3:2008
Relative Humidity
۵to 85% at 104° F (40° C)
Certifications/Susceptibility Standards
ETSI EN 300 386 V1.6.1 (2012); EN 55032:2012/AC:2013
EN 61000-3-2:2014; EN 61000-3-3:2013; EN 55024:2010;
FCC Class A (Part 15), IC Class A; VCCI Class A
FCC Part 15 Class A
VCCI Class A
ETSI EN 300 386 V1.5.1 (2010)
EN 55022:2010 Class A
EN 61000-3-2:2006 A1:2009+A2:2009
EN 61000-3-3:2008
EN 55024:2010
EN 55022:2010 Class A
EN 61000-3-2:2006 A1:2009+A2:2009
EN 61000-3-3:2008