company
Palo Alto
f5
f5
Firewall throughput
۱۵.۲/۱۷Gbps
Threat prevention throughput
۷.۷/۹.۷Gbps
IPsec VPN throughput
۹.۷Gbps
max sessions
۴,۰۰۰,۰۰۰
new sessions per second
۱۶۶,۰۰۰
virtual systems (base/max4)
۱۰/۲۰
Intelligent Traffic Processing
L7 requests per second: 4M
L4 connections per second: 1.5M
L4 HTTP requests per second: 14M
Maximum L4 concurrent connections: 80M
Throughput: 84 Gbps/40 Gbps L4/L7
Hardware Offload SSL/TLS
Included: 240K TPS (2K keys)
Maximum: 240K TPS (2K keys)
۴۰ Gbps bulk encryption*
FIPS SSL
N/A
Hardware Compression
Included: 40 Gbps, Maximum: 40 Gbps
Hardware DDoS Protection
۸۰M SYN cookies per second
TurboFlex Performance Profiles
N/A
Software Compression
N/A
Software Architecture
۶۴-bit TMOS
On-Demand Upgradable
N/A
Virtualization (Maximum Number of vCMP Guests)
۲۴
Processor
One 12-Core Intel Xeon processor
(total 24 hyperthreaded logical processor cores)
Memory
۱۲۸ GB
Hard Drive
۸۰۰ GB SSD
Gigabit Ethernet CU Ports
Optional SFP
Gigabit Fiber Ports (SFP)
Optional SFP+ (SX or LX)
۱۰ Gigabit Fiber Ports (SFP+)
۱۶ SR or LR (sold separately, 2 SR included);
Optional 10G copper direct attach
۴۰ Gigabit Fiber Ports (QSFP+)
۲ SR4 (sold separately) (QSFP+ optical breakout cable
assemblies available to convert to 10 gigabit ports)
Power Supply
Dual 850W included (80+ Platinum efficiency), DC optional
AC power supply
One to two 100-240 VAC (800W)
۵۰/۶۰ Hz auto ranging
۱۰A per input line (max)
DC power supply (option)
Typical Consumption
۳۳۰W (dual supply, 110V input)
Input Voltage
۹۰–۲۴۰ VAC +/- 10% auto switching, 50/60hz
Typical Heat Output
۱۱۲۵ BTU/hour (dual supply, 110V input)
Dimensions
۳.۴۵” (۸.۷۶ cm) H x 17.3” (۴۳.۹۴ cm) W x 21.4” (۵۴.۳۶ cm) D
۲U industry standard rack-mount chassis
۳.۴”(۸.۶ cm)H x 17.3”(۴۴.۰ cm) W x 24.5” (۶۲.۲ cm) D
۲U industry standard rack-mount chassis
Weight
۴۳ lbs. (19.5 kg) (Dual power supply)
۳۱.0lbs.(14.1 kg)(1 blank line card, 0 power supplies, 0 blades, 1 fan tray)
Operating Temperature
۳۲° to 104° F (0° to 40° C)
۳۲°to 104° F (0° to 40° C)
Operational Relative Humidity
۱۰% to 90% at 40º C
Safety Agency Approval
UL 60950-1 2nd Edition
CAN/CSA C22.2 No. 60950-1-07
EN 60950-1:2006, 2nd Edition
IEC 60950-1:2006, 2nd Edition
Evaluated to all CB Countries
EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011
IEC 60950-1:2005, A1:2009
CSA 60950-1-07, Including Amendment 1:2011
ANSI/UL 60950-1-2011
Evaluated to all CB Countries
Certifications/ Susceptibility Standards
EEN 300 386 V1.5.1 (2010-10)
EN 55022:2006+A1:2007; EN 61000-3-2:2006
EN 61000-3-3:1995+A1:2000+A2:2005
EN 55024: 2010; USA FCC Class A
VCCI Class A
FCC Part 15 Class A
VCCI Class A
ETSI EN 300 386 V1.5.1 (2010)
EN 55022:2010 Class A
EN 61000-3-2:2006 A1:2009+A2:2009
EN 61000-3-3:2008
EN 55024:2010
EN 55022:2010 Class A
EN 61000-3-2:2006 A1:2009+A2:2009
EN 61000-3-3:2008
Relative Humidity
۵to 85% at 104° F (40° C)
Certifications/Susceptibility Standards
EEN 300 386 V1.5.1 (2010-10)
EN 55022:2006+A1:2007; EN 61000-3-2:2006
EN 61000-3-3:1995+A1:2000+A2:2005
EN 55024: 2010; USA FCC Class A
VCCI Class A
FCC Part 15 Class A
VCCI Class A
ETSI EN 300 386 V1.5.1 (2010)
EN 55022:2010 Class A
EN 61000-3-2:2006 A1:2009+A2:2009
EN 61000-3-3:2008
EN 55024:2010
EN 55022:2010 Class A
EN 61000-3-2:2006 A1:2009+A2:2009
EN 61000-3-3:2008