• Firewall throughput (HTTP/appmix)
  • ۱۲۰Gbps



  • Threat Prevention throughput (DSRI enabled)
  • ۱۰۰Gbps



  • Threat Prevention throughput (HTTP/appmix)
  • ۶۰Gbps



  • IPSec VPN throughput
  • ۴۸Gbps



  • Max sessions
  • ۴۸M



  • New sessions per second
  • ۷۲۰,۰۰۰



  • Virtual systems (base/max)
  • ۲۵/۲۲۵



  • Firewall

  • ۲۴۰Gbps


  • Threat Protection Throughput

  • ۲۳Gbps


  • Firewall Policies

  • ۲۰۰,۰۰۰


  • Virtual Domains (Default / Maximum)

  • ۱۰/۵۰۰


  • High Availability Configurations

  • Active/Active, Active/Passive, Clustering


  • Console (RJ45)

  • ۱


  • Firewall Throughput (1518/512/64 byte UDP packets)

  • ۲۴۰/۲۳۸/۱۵۰ Gbps


  • Firewall Latency( 64byte UDP packets )

  • ۴μs


  • Concurrent Sessions ( TCP )

  • ۵۰Million


  • New Sessions/Sec(TCP)

  • ۴۶۰,۰۰۰


  • IPsec VPN Throughput (512 byte)

  • ۱۴۰Gbps


  • SSL VPN Throughput

  • ۱۱Gbps


  • Concurrent SSL VPN Users (Recommended Maximum, Tunnel Mode)

  • ۳۰,۰۰۰


  • IPS Throughput

  • ۴۴Gbps


  • Application Control Throughput (HTTP 64K)

  • ۸۶Gbps


  • NGFW Throughput

  • ۳۴Gbps


  • Threat Protection Throughput (Ent. Mix)

  • ۲۳Gbps


  • company

  • Fortinet
    f5
    f5
  • Dimensions


  • ۳.۴”(۸.۶ cm)H x 17.3”(۴۴.۰ cm) W x 24.5” (۶۲.۲ cm) D ۲U industry standard rack-mount chassis
    ۱۲.۲”(۳۰.۹ cm)Hx17.4”(۴۴.۲ cm)Wx21”(۵۳.۳ cm)D7U industry standard rack-mount chassis
  • Weight


  • ۳۱.0lbs.(14.1 kg)(1 blank line card, 0 power supplies, 0 blades, 1 fan tray)
    ۸۷lbs.(39.5 kg)(4power supplies, 1fan trays,3blanks)
  • Power Supply


  • AC power supply One to two 100-240 VAC (800W) ۵۰/۶۰ Hz auto ranging ۱۰A per input line (max) DC power supply (option)
    One to four 90 VAC (1200W) to 240 VAC (2000W) auto ranging20A per input line (max)DC power (option)One to four 1200W -36 to -72 VDC10 to 40A maximum per supply Note: Please refer to the Platform Guide: VIPRION 4400on askf5.com for the latest specific AC power ratings.
  • Operating Temperature


  • ۳۲°to 104° F (0° to 40° C)
    ۳۲°to 104° F (0° to 40° C)
  • Relative Humidity


  • ۵to 85% at 104° F (40° C)
    ۵to 85% at 104° F (40° C)
  • Safety Agency Approval


  • EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011 IEC 60950-1:2005, A1:2009 CSA 60950-1-07, Including Amendment 1:2011 ANSI/UL 60950-1-2011 Evaluated to all CB Countries
    UL60950 (UL1950-3) CSA-C22.2 No. 60950-00(bi-national standard with UL 60950) CB test certification to IEC 950 EN 60950
  • Certifications/Susceptibility Standards


  • FCC Part 15 Class A VCCI Class A ETSI EN 300 386 V1.5.1 (2010) EN 55022:2010 Class A EN 61000-3-2:2006 A1:2009+A2:2009 EN 61000-3-3:2008 EN 55024:2010 EN 55022:2010 Class A EN 61000-3-2:2006 A1:2009+A2:2009 EN 61000-3-3:2008
    EN55022 1998 Class A EN55024 1998 Class A FCC Part 15B Class A VCCI Class A NEBS Certified