• Firewall
  • ۲۴۰Gbps



  • Threat Protection Throughput
  • ۳۰Gbps



  • Firewall Policies
  • ۲۰۰,۰۰۰



  • Virtual Domains (Default / Maximum)
  • ۱۰/۵۰۰



  • High Availability Configurations
  • Active/Active, Active/Passive, Clustering



  • Console port
  • ۱



  • Firewall Throughput (1518/512/64 byte UDP packets)
  • ۲۴۰/۲۴۰/۱۵۰ Gbps



  • Firewall Latency( 64byte UDP packets )
  • ۴μs



  • Concurrent Sessions ( TCP )
  • ۵۰Million



  • New Sessions/Sec(TCP)
  • ۴۶۰,۰۰۰



  • IPsec VPN Throughput (512 byte)
  • ۱۴۵Gbps
    ۲۵ Gbps


  • SSL VPN Throughput
  • ۱۲Gbps



  • Concurrent SSL VPN Users (Recommended Maximum, Tunnel Mode)
  • ۳۰,۰۰۰



  • IPS Throughput
  • ۵۵Gbps
    ۸ Gbps


  • Application Control Throughput (HTTP 64K)
  • ۹۵Gbps



  • NGFW Throughput
  • ۴۰Gbps



  • Threat Protection Throughput (Ent. Mix)
  • ۳۰Gbps



  • company
  • Fortinet
    Fortinet

    f5
  • Firewall Throughput (Packet per Second):

  • ۴۹.۵ Mpps


  • Firewall Latency (64 byte, UDP):

  • ۳µs


  • IPsec VPN Throughput (512 byte):
  • ۱۴۵Gbps
    ۲۵ Gbps


  • IPS Throughput:
  • ۵۵Gbps
    ۸ Gbps


  • Antivirus Throughput:

  • ۳.۵ Gbps


  • Redundant Power Supplies:

  • Yes


  • Hardware Accelerated GE SFP Slots:

  • ۱۶


  • Hardware Accelerated GE RJ45 Ports:

  • ۱۶


  • Firewall throughput (HTTP/appmix)


  • ۱۲۰Gbps

  • Threat Prevention throughput (DSRI enabled)


  • ۱۰۰Gbps

  • Threat Prevention throughput (HTTP/appmix)


  • ۶۰Gbps

  • IPSec VPN throughput


  • ۴۸Gbps

  • Max sessions


  • ۴۸M

  • New sessions per second


  • ۷۲۰,۰۰۰

  • Virtual systems (base/max)


  • ۲۵/۲۲۵

  • Weight



  • ۱۲۶lbs.(57.2 kg)(2 power supplies, 2 fan trays, 8 blanks)
  • Power Supply



  • One to four 200 VAC to 240 VAC (2600W) auto ranging (80+ Gold Efficiency) (2 power supplies included)18A per input (max)DC power (option)One to four 2600W -44 to -72 VDC 80A per input maximum per supply Note: Please refer to the Platform Guide: VIPRION 4800on askf5.com for the latest specific AC power ratings.
  • Operating Temperature



  • ۳۲°to 104° F (0° to 40° C)
  • Relative Humidity



  • ۵to 85% at 104° F (40° C)
  • Safety Agency Approval



  • UL60950 (UL1950-3) CSA-C22.2 No. 60950-00(bi-national standard with UL 60950) CB test certification to IEC 950 EN 60950
  • Certifications/Susceptibility Standards



  • EN55022 1998 Class A EN55024 1998 Class A FCC Part 15B Class A VCCI Class A
  • Dimensions



  • ۲۷.۸”(۷۰.۶ cm)Hx17.4”(۴۴.۲ cm)Wx21.25”(۵۴.۰ cm)D16U industry standard rack-mount chassis