company
Fortinet
cisco
Fortinet
f5
Devices/VDOMs (Maximum)
۱۰۰۰
Sustained Log Rates
۵۰
GB Log / Day
۲
Storage Capacity
۳۲TB (8 x 4 TB)
Usable Storage (after RAID)
۲۴TB
RAID Levels Supported
RAID 0/1/5/6/10/50/60
Hardware Form Factor
۲RU Rackmount
Total Interfaces
۲xRJ45 10G ports, 2xSFP + ports
Console Port
DB-9
Removable Hard Drives
Yes
Redundant Hot Swap Power Supplies
Yes
Chassis Management
Yes
Height x Width x Length (cm)
۸.۹x 43.7 x 65
AC Power Supply
۱۰۰-۲۴۰V AC, 50-60 Hz
Power Consumption (Average / Maximum)
۶۵W / 130W
Heat Dissipation
۹۲۰ BTU/h
Operating Temperature
۵۰-۹۵°F (10–۳۵°C)
۳۲°F to 104°F
Safety Certifications
FCC Part 15 Class A, C-Tick, VCCI, CE, UL/cUL, CB
Throughput: Firewall (FW) + Application Visibility and Control (AVC)(1024B)
۱۴۸Gbps
Throughput: FW + AVC + Intrusion Prevention System (IPS (1024B)
۱۳۲Gbps
Maximum concurrent sessions, with AVC
۶۳million
Maximum new connections per second, with AVC
۸۵۰K
TLS (Hardware Decryption)
۲۵Gbps
Throughput: NGIPS (1024B)
۱۴۸Gbps
IPSec VPN throughput (1024B TCP w/Fastpath)
۵۱Gbps
MaximumVPN Peers
۶۰,۰۰۰
URL filtering: number of categories
More than 80
URL filtering: number of URLs categorized
More than 280 million
Stateful inspection firewall throughput
۲۳۴Gbps
Stateful inspection firewall throughput (multiprotocol)
۱۳۰Gbps
Concurrent firewall connections
۷۰million
Firewall latency (UDP 64B microseconds)
۳.۵
New connections persecond
۴million
High availability
Active/active and active/standby
Scalability
VPN load balancing, firewall clustering
Cisco Security Intelligence
Standard, with IP, URL, and DNS threat intelligence
Cisco Firepower NGIPS
Available; can passively detect endpoints and infrastructure for threat correlation and Indicators of Compromise (IoC) intelligence
Clustering
Up to 16 security modules across up to 16 different Firepower 9300 chassis
Centralized management
Centralized configuration, logging, monitoring, and reporting are performed by Cisco Security Manager or alternatively in the cloud with Cisco Defense Orchestrator
Adaptive Security Device Manager
Web-based, local management for small-scale deployments
Firewall
۲۴۰Gbps
Threat Protection Throughput
۲۳Gbps
Firewall Policies
۲۰۰,۰۰۰
Virtual Domains (Default / Maximum)
۱۰/۵۰۰
High Availability Configurations
Active/Active, Active/Passive, Clustering
Console (RJ45)
۱
Firewall Throughput (1518/512/64 byte UDP packets)
۲۴۰/۲۳۸/۱۵۰ Gbps
Firewall Latency( 64byte UDP packets )
۴μs
Concurrent Sessions ( TCP )
۵۰Million
New Sessions/Sec(TCP)
۴۶۰,۰۰۰
IPsec VPN Throughput (512 byte)
۱۴۰Gbps
SSL VPN Throughput
۱۱Gbps
Concurrent SSL VPN Users (Recommended Maximum, Tunnel Mode)
۳۰,۰۰۰
IPS Throughput
۴۴Gbps
Application Control Throughput (HTTP 64K)
۸۶Gbps
NGFW Throughput
۳۴Gbps
Threat Protection Throughput (Ent. Mix)
۲۳Gbps
Intelligent Traffic Processing
L7 requests per second: 650K
L4 connections per second: 250K
L4 HTTP requests per second: 1M
Maximum L4 concurrent connections: 28M
Throughput: 20 Gbps L4/L7
Hardware Offload SSL/TLS
ECC†: ۶.۵K TPS (ECDSA P-256)
RSA: 10K TPS (2K keys)
۱۰ Gbps bulk encryption
FIPS SSL
N/A
Hardware Compression
N/A
Hardware DDoS Protection
N/A
TurboFlex Performance Profiles
N/A
Software Compression
۶ Gbps
Software Architecture
۶۴-bit TMOS
On-Demand Upgradable
Yes
Virtualization (Maximum Number of vCMP Guests)
N/A
Processor
One 4-Core Intel Xeon processor
(total 8 hyperthreaded logical processor cores)
Memory
۳۲ GB DDR4
Hard Drive
۱x 500 GB Enterprise Class HDD
Gigabit Ethernet CU Ports
Optional SFP
Gigabit Fiber Ports (SFP)
۸ SX or LX (sold separately)
۱۰ Gigabit Fiber Ports (SFP+)
۴ SR/LR (sold separately); optional 10G copper direct attach
۴۰ Gigabit Fiber Ports (QSFP+)
N/A
Power Supply
۱x 250W Platinum AC PSU (Additional PSU optional,
۲x 650W DC PSU Option)
Typical Consumption
۱۳۰W (single power supply, 110V input)
Input Voltage
۱۰۰-۲۴۰ VAC +/- 10% auto switching, 50/60hz
Typical Heat Output
۴۴۵ BTU/hour (single power supply, 110V input)
Dimensions
۱.۷۲” (۴.۳۷ cm) H x 17.4” (۴۴.۲ cm) W x 22.5” (۵۷.۱۵ cm) D
۱U industry standard rack-mount chassis
Weight
۲۰ lbs. (9.07 kg) (single power supply)
Operational Relative Humidity
۵% to 85% at 40º C
Safety Agency Approval
ANSI/UL 60950-1-2014
CSA 60950-1-07, including A1:2011+A2:2014
IEC 60950-1:2005, A1:2009+A2:2013
EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013
Certifications/ Susceptibility Standards
ETSI EN 300 386 V1.6.1 (2012)
EN 55032:2012 Class A; EN 61000-3-2:2014
EN 61000-3-3:2013; EN 55024:2010
FCC Class A (Part 15), IC Class A, VCCI Class A