company
Fortinet
Fortinet
cisco
f5
GB/Day of Logs
۸,۳۰۰
Analytic Sustained Rate (logs/sec)
۱۰۰,۰۰۰
Collector Sustained Rate (logs/sec)
۱۵۰,۰۰۰
Devices/VDOMs (Maximum)
۱۰,۰۰۰
Max Number of Days Analytics
۶۰
FortiGuard Indicator of Compromise (IOC)
Yes
Form Factor
۴RU Rackmount
Total Interfaces
+۲x 1GE, 2x SFP
Storage Capacity
۲۴۰TB (60 x 4 TB)
Usable Storage (After RAID)
۲۱۶TB
Removable Hard Drives
Yes
RAID Levels Supported
RAID 0/1/5/6/10/50/60
RAID Type
Hardware / Hot Swappable
Default RAID Level
۵۰
Redundant Hot Swap Power Supplies
Yes
Height x Width x Length (cm)
۱۷.۸x 43.7 x 76.7
AC Power Supply
۱۰۰-۲۴۰V AC, 50–۶۰ Hz
Power Consumption (Average / Maximum)
۸۵۰W / 1423.4W
Heat Dissipation
۴۸۵۸BTU/h
Safety Certifications
FCC Part 15 Class A, C-Tick, VCCI, CE, UL/cUL, CB
Firewall
۱۶۰Gbps
IPS
۲۷Gbps
NGFW
۲۳Gbps
Threat Protection
۱۷Gbps
Interfaces
Multiple GE RJ45, 25 GE SFP28/10 GE SFP+ and 40 GE QSFP+ slots
Throughput: Firewall (FW) + Application Visibility and Control (AVC)(1024B)
۱۶۸ Gbps
Throughput: FW + AVC + Intrusion Prevention System (IPS (1024B)
۱۵۳ Gbps
Maximum concurrent sessions, with AVC
۶۰ million
Maximum new connections per second, with AVCs
۱.۱M
TLS (Hardware Decryption)
۲۸ Gbps
Throughput: NGIPS (1024B)
۱۷۵ Gbps
IPSec VPN throughput (1024B TCP w/Fastpath)
۸۱ Gbps
Centralizedmanagement
Centralized configuration, logging, monitoring, and reporting are performed by the Management Center or alternatively in the cloud with Cisco Defense Orchestrator
AVC
Standard, supporting more than 4000 applications, as well as geolocations, users, and websites
AVC: OpenAppID support for custom, open-source application detectors
Standard
Cisco Security Intelligence
Standard, with IP, URL, and DNS threat intelligence
URL filtering: number of categories
More than 80
URL filtering: number of URLs categorized
More than 280 million
Stateful inspection firewall throughput
۲۳۵ Gbps
Stateful inspection firewall throughput (multiprotocol)
۱۷۲ Gbps
Concurrent firewall connections
۱۹۵ million
Firewall latency (UDP 64B microseconds)
۳.۵
New connections persecond
۴.۷۵ million
IPsec VPN throughput (450B UDP L2L test)
۷۴ Gbps
MaximumVPN Peers
۶۰,۰۰۰
Security contexts (included; maximum)
۱۰; ۲۵۰
High availability
Active/active and active/standby
Clustering
Up to 16 security modules across up to 16 different Firepower 9300 chassis
Scalability
VPN load balancing, firewall clustering
Centralized management
Centralized configuration, logging, monitoring, and reporting are performed by Cisco Security Manager or alternatively in the cloud with Cisco Defense Orchestrator
Adaptive Security Device Manager
Web-based, local management for small-scale deployments
Intelligent Traffic Processing
L7 requests per second: 750K
L4 connections per second: 350K
L4 HTTP requests per second: 3.5M
Maximum L4 concurrent connections: 24M
Throughput: 30 Gbps/15 Gbps L4/L7
Hardware Offload SSL/TLS
Included: 10,000 TPS (2K keys)
Maximum: 10,000 TPS (2K keys)
۱۲ Gbps bulk encryption*
FIPS SSL
N/A
Hardware DDoS Protection
N/A
Hardware Compression
۲۰M SYN cookies per second
TurboFlex Performance Profiles
N/A
Software Compression
Included: 6 Gbps
Maximum: 6 Gbps
Software Architecture
۶۴-bit TMOS
On-Demand Upgradable
Yes
Virtualization (Maximum Number of vCMP Guests)
N/A
Processor
۱ quad core Intel Xeon processor
(total 8 hyperthreaded logical processing cores)
Memory
۳۲ GB
Hard Drive
۱ TB (5000s)
۴۰۰ GB solid state drive (5050s)
Gigabit Ethernet CU Ports
۴
Gigabit Fiber Ports (SFP)
Optional SFP (SX, LX, or copper)
۱۰ Gigabit Fiber Ports (SFP+)
۸ SR or LR (sold separately);
Optional 10G copper direct attach
۴۰ Gigabit Fiber Ports (QSFP+)
N/A
Power Supply
One 400W included (80 Plus Gold Efficiency),
dual power and DC optional
Typical Consumption
۱۶۵W (single supply, 110V input)
Input Voltage
۹۰-۲۴۰ VAC +/- 10% auto switching, 50/60hz
Typical Heat Output
۵۶۴ BTU/hour (single supply, 110V input)
Dimensions
۱.۷۵” (۴.۴۵ cm) H x 17” (۴۳.۱۸ cm) W x 21” (۵۳.۳۴ cm) D
۱U industry standard rack-mount chassis
Weight
۲۱ lbs. (9.53 kg) (one power supply)
Operating Temperature
۳۲° to 104° F (0° to 40° C)
Operational Relative Humidity
۵% to 85% at 40° C
Safety Agency Approval
ANSI/UL 60950-1-2011
CSA 60950-1-07, including Amendment 1:2011
Low Voltage Directive 2006/95/EC; CB Scheme
EN 60950-1:2006+A11:2009+A1:2010+A12:2011
IEC 60950-1:2005, A1:200
Certifications/ Susceptibility Standards
EN 300 386 V1.5.1 (2010-10); EN 55022:2010
EN 61000-3-2:2006+A1:2009+A2:2009; EN 61000-3-3:2008
EN 55024:2010; EN 55022:2010; EN 61000-3-3:2008
EN 55024:2010; USA FCC Class A; VCCI Class A