company
Fortinet
f5
GB/Day of Logs
۸,۳۰۰
Analytic Sustained Rate (logs/sec)
۱۰۰,۰۰۰
Collector Sustained Rate (logs/sec)
۱۵۰,۰۰۰
Devices/VDOMs (Maximum)
۱۰,۰۰۰
Max Number of Days Analytics
۶۰
FortiGuard Indicator of Compromise (IOC)
Yes
Form Factor
۴RU Rackmount
Total Interfaces
+۲x 1GE, 2x SFP
Storage Capacity
۲۴۰TB (60 x 4 TB)
Usable Storage (After RAID)
۲۱۶TB
Removable Hard Drives
Yes
RAID Levels Supported
RAID 0/1/5/6/10/50/60
RAID Type
Hardware / Hot Swappable
Default RAID Level
۵۰
Redundant Hot Swap Power Supplies
Yes
Height x Width x Length (cm)
۱۷.۸x 43.7 x 76.7
AC Power Supply
۱۰۰-۲۴۰V AC, 50–۶۰ Hz
Power Consumption (Average / Maximum)
۸۵۰W / 1423.4W
Heat Dissipation
۴۸۵۸BTU/h
Safety Certifications
FCC Part 15 Class A, C-Tick, VCCI, CE, UL/cUL, CB
Intelligent Traffic Processing
L7 requests per second: 850K
L4 connections per second: 300K
L4 HTTP requests per second: 2.5M
Maximum L4 concurrent connections: 10M
Throughput: 10 Gbps L4/L7
Hardware Offload SSL/TLS
Included: 9,000 TPS (2K keys)
Maximum: 9,000 TPS (2K keys)
۸ Gbps bulk encryption*
FIPS SSL
N/A
Hardware DDoS Protection
Included: 8 Gbps
Maximum: 8 Gbps
Hardware Compression
N/A
TurboFlex Performance Profiles
N/A
Software Compression
N/A
Software Architecture
۶۴-bit TMOS
On-Demand Upgradable
Yes
Virtualization (Maximum Number of vCMP Guests)
N/A
Processor
۱ quad core Intel Xeon processor
(total 8 hyperthreaded logical processing cores)
Memory
۱۶ GB
Hard Drive
۵۰۰ GB
Gigabit Ethernet CU Ports
۸
Gigabit Fiber Ports (SFP)
Optional SFP (SX, LX, or copper)
۱۰ Gigabit Fiber Ports (SFP+)
۲ SR or LR (sold separately);
Optional 10G copper direct attach
۴۰ Gigabit Fiber Ports (QSFP+)
N/A
Power Supply
One 400W included (80 Plus Platinum efficiency),
dual power and DC optional
Typical Consumption
۹۵W (single supply, 110V input)
Input Voltage
۹۰-۲۴۰ VAC +/- 10% auto switching, 50/60hz
Typical Heat Output
۳۲۴ BTU/hour (single supply, 110V input)
Dimensions
۱.۷۵” (۴.۴۵ cm) H x 17” (۴۳.۱۸ cm) W x 21” (۵۳.۳۴ cm) D
۱U industry standard rack-mount chassis
Weight
۲۰ lbs. (9.1 kg) (one power supply)
Operating Temperature
۳۲° to 104° F (0° to 40° C)
Operational Relative Humidity
۵% to 85% at 40° C
Safety Agency Approval
UL 60950-1 2nd Edition
CAN/CSA C22.2 No. 60950-1-07
EN 60950-1:2006, 2nd Edition
IEC 60950-1:2006, 2nd Edition
Evaluated to all CB Countries
Certifications/ Susceptibility Standards
EN 300 386 V1.5.1 (2010-10); EN 55022:2006+A1:2007
EN 61000-3-2:2006; EN 61000-3-3:1995+A1:2000+A2:2005
EN 55024:2010; USA FCC Class A; VCCI Class A