company
f5
f5
Fortinet
f5
Intelligent Traffic Processing
L7 requests per second: 3M
L4 connections per second: 1.2M
L4 HTTP requests per second: 14M
Maximum L4 concurrent connections: 80M
Throughput: 80 Gbps/40 Gbps
L7 requests per second: 212K
L4 connections per second: 75K
L4 HTTP requests per second: 550K
Maximum L4 concurrent connections: 5M
Throughput: 5 Gbps L4/L7
Hardware Offload SSL/TLS
ECC†: ۲۵K TPS (ECDSA P-256)
RSA: 40K TPS (2K keys)
۲۰ Gbps bulk encryption
Included: 2,000 TPS (2K keys)
Maximum: 2,000 TPS (2K keys)
۴ Gbps bulk encryption*
FIPS SSL
۱۳k TPS (FIPS 140-2 Level 3)
N/A
Hardware Compression
۲۰ Gbps
N/A
Hardware DDoS Protection
۷۰M SYN cookies per second
N/A
TurboFlex Performance Profiles
Tier 3
N/A
Software Compression
N/A
Included: 2.5 Gbps
Maximum: 2.5 Gbps
Software Architecture
۶۴-bit TMOS
۶۴-bit TMOS
On-Demand Upgradable
N/A
Yes
Virtualization (Maximum Number of vCMP Guests)
۱۲
N/A
Processor
One 6-Core Intel Xeon processor (total 12 hyperthreaded
logical processor cores)
Intel dual core (total 4 hyperthreaded logical
processing cores)
Memory
۹۶ GB DDR4
۸ GB
Hard Drive
Dual SSD 2x 480GB Enterprise Class SSD
۵۰۰ GB
Gigabit Ethernet CU Ports
Optional SFP
۸
Gigabit Fiber Ports (SFP)
Optional SFP+ (SX or LX)
Optional SFP (SX, LX, or copper)
۱۰ Gigabit Fiber Ports (SFP+)
۸ SR/LR (sold separately); optional 10G copper direct attach
۲ SR or LR (sold separately);
Optional 10G copper direct attach
۴۰ Gigabit Fiber Ports (QSFP+)
۴ SR4/LR4 (sold separately) (QSFP+ optical breakout cable
assemblies available to convert to 10G ports)
N/A
Power Supply
۲x 650W Platinum AC PSU (2x 650W DC PSU Option)
One 400W included (80+ Platinum efficiency),
dual power and DC optional
One to four 90 VAC (1200W) to 240 VAC (2000W) auto ranging20A per input line (max)DC power (option)One to four 1200W -36 to -72 VDC10 to 40A maximum per supply
Note: Please refer to the Platform Guide: VIPRION 4400on askf5.com for the latest specific AC power ratings.
Typical Consumption
۳۱۰W (dual power supply, 110V input)
۷۴W (single supply, 110V input)
Input Voltage
۱۰۰-۲۴۰ VAC +/- 10% auto switching, 50/60hz
۹۰–۲۴۰ VAC +/- 10% auto switching, 50/60hz
Typical Heat Output
۱۱۶۵ BTU/hour (dual power supply, 110V input)
۲۵۲ BTU/hour (single supply, 110V input)
Dimensions
۱.۷۲” (۴.۳۷ cm) H x 17.4” (۴۴.۲ cm) W x 30.6” (۷۷.۷۲ cm) D
۱U industry standard rack-mount chassis
۱.۷۵” (۴.۴۵ cm) H x 17” (۴۳.۱۸ cm) W x 21” (۵۳.۳۴ cm) D
۱U industry standard rack-mount chassis
۱۲.۲”(۳۰.۹ cm)Hx17.4”(۴۴.۲ cm)Wx21”(۵۳.۳ cm)D7U industry standard rack-mount chassis
Weight
۳۰ lbs. (13.6 kg) (dual power supply)
۲۰ lbs. (9.1 kg) (one power supply)
۸۷lbs.(39.5 kg)(4power supplies, 1fan trays,3blanks)
Operating Temperature
۳۲° to 104° F (0° to 40° C)
۳۲° to 104° F (0° to 40° C)
۳۲°to 104° F (0° to 40° C)
Operational Relative Humidity
۵% to 85% at 40° C
۵% to 85% at 40° C
Safety Agency Approval
ANSI/UL 60950-1-2014
CSA 60950-1-07, including A1:2011+A2:2014
IEC 60950-1:2005, A1:2009+A2:2013
EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013
UL 60950-1 2nd Edition
CAN/CSA C22.2 No. 60950-1-07
EN 60950-1:2006, 2nd Edition
IEC 60950-1:2006, 2nd Edition
Evaluated to all CB Countries
UL60950 (UL1950-3) CSA-C22.2 No. 60950-00(bi-national standard with UL 60950) CB test certification to IEC 950 EN 60950
Certifications/ Susceptibility Standards
ETSI EN 300 386 V1.6.1 (2012); EN 55032:2012/AC:2013
EN 55032:2012 Class A; EN 61000-3-2:2014
EN 61000-3-3:2013; EN 55024:2010
FCC Class A (Part 15), IC Class A, VCCI Class A
EN 300 386 V1.5.1 (2010-10); EN 55022:2006+A1:2007
EN 61000-3-2:2006
EN 61000-3-3:1995+A1:2000+A2:2005
EN 55024: 2010; USA FCC Class A; VCCI Class A
EN55022 1998 Class A
EN55024 1998 Class A
FCC Part 15B Class A
VCCI Class A
NEBS Certified
GB/Day of Logs
۱۵۰
Analytic Sustained Rate (logs/sec)
۴۵۰۰
Collector Sustained Rate (logs/sec)
۶۷۵۰
Devices/VDOMs (Maximum)
۱۸۰
Max Number of Days Analytics
۲۸
FortiGuard Indicator of Compromise (IOC)
Yes
Form Factor
۱RU Rackmount
Total Interfaces
۲x RJ45 GE, 2 x SFP
Storage Capacity
۸TB (2 x 4 TB)
Usable Storage (After RAID)
۴TB
Removable Hard Drives
No
RAID Levels Supported
RAID 0/1
RAID Type
Software
Default RAID Level
۱
Redundant Hot Swap Power Supplies
No
Height x Width x Length (cm)
۴.۴x 43.2 x 38.0
AC Power Supply
۱۰۰-۲۴۰V AC, 60–۵۰ Hz
Power Consumption (Average / Maximum)
۶۵W / 130W
Heat Dissipation
۴۴۵BTU/h
Safety Certifications
FCC Part 15 Class A, C-Tick, VCCI, CE, UL/cUL, CB
Relative Humidity
۵to 85% at 104° F (40° C)
Certifications/Susceptibility Standards
ETSI EN 300 386 V1.6.1 (2012); EN 55032:2012/AC:2013
EN 55032:2012 Class A; EN 61000-3-2:2014
EN 61000-3-3:2013; EN 55024:2010
FCC Class A (Part 15), IC Class A, VCCI Class A
EN 300 386 V1.5.1 (2010-10); EN 55022:2006+A1:2007
EN 61000-3-2:2006
EN 61000-3-3:1995+A1:2000+A2:2005
EN 55024: 2010; USA FCC Class A; VCCI Class A
EN55022 1998 Class A
EN55024 1998 Class A
FCC Part 15B Class A
VCCI Class A
NEBS Certified