company
f5
juniper
Fortinet
f5
Intelligent Traffic Processing
L7 requests per second: 3M
L4 connections per second: 1.2M
L4 HTTP requests per second: 14M
Maximum L4 concurrent connections: 80M
Throughput: 84 Gbps/40 Gbps L4/L7
Hardware Offload SSL/TLS
Included: 42K TPS (2K keys)
Maximum: 42K TPS (2K keys)
۲۴ Gbps bulk encryption
FIPS SSL
FIPS 140-2 Level 3 (10350v-F only)
۳۵,۰۰۰ TPS (2K keys) (10350v-F only)
۲۴ Gbps bulk encryption (10350v-F only)
Hardware Compression
Included: 24 Gbps; Maximum: 24 Gbps
Hardware DDoS Protection
۸۰M SYN cookies per second
TurboFlex Performance Profiles
N/A
Software Compression
N/A
Software Architecture
۶۴-bit TMOS
On-Demand Upgradable
N/A
Virtualization (Maximum Number of vCMP Guests)
۲۰
Processor
One 10-Core Intel Xeon processor
(total 20 hyperthreaded logical processor cores)
Memory
۱۲۸ GB
Hard Drive
۸۰۰ GB SSD
Gigabit Ethernet CU Ports
Optional SFP
Gigabit Fiber Ports (SFP)
Optional SFP (SX or LX)
۱۰ Gigabit Fiber Ports (SFP+)
۱۶ SR or LR (sold separately, 2 SR included);
Optional 10G copper direct attach
۴۰ Gigabit Fiber Ports (QSFP+)
۲ SR4 (sold separately) (QSFP+ optical breakout cable
assemblies available to convert to 10 gigabit ports)
Power Supply
Dual 850W included (80+Platinum efficiency),
AC (10350v) or DC (10350v-N)
AC power supply
One to two 100-240 VAC (800W)
۵۰/۶۰ Hz auto ranging
۱۰A per input line (max)
DC power supply (option)
Typical Consumption
۳۲۰W (dual supply, 48V DC or 110V AC input)
Input Voltage
Operating range: 44 to 72 VDC
Minimum start up voltage: 44 VDC
Typical Heat Output
۱۰۹۵ BTU/hour (dual supply, 48V DC or 110V AC input)
Dimensions
۳.۴۵“ (۸.۷۶ cm) H x 17.3” (۴۳.۹۴ cm) W x 21.4” (۵۴.۳۶ cm) D
۲U industry standard rack-mount chassis
۳.۴”(۸.۶ cm)H x 17.3”(۴۴.۰ cm) W x 24.5” (۶۲.۲ cm) D
۲U industry standard rack-mount chassis
Weight
۴۳ lbs. (19.5 kg) (dual power supply)
۳۱.0lbs.(14.1 kg)(1 blank line card, 0 power supplies, 0 blades, 1 fan tray)
Operating Temperature
۳۲° to 104° F (0° to 40° C)
۳۲°to 104° F (0° to 40° C)
Operational Relative Humidity
۱۰% to 90% at 40º C
Safety Agency Approval
UL 60950-1 2nd Edition; CAN/CSA C22.2 No. 60950-1-07
EN 60950-1:2006, 2nd Edition; IEC 60950-1:2006, 2nd
Edition
Evaluated to all CB Countries
EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011
IEC 60950-1:2005, A1:2009
CSA 60950-1-07, Including Amendment 1:2011
ANSI/UL 60950-1-2011
Evaluated to all CB Countries
Certifications/ Susceptibility Standards
EEN 300 386 V1.5.1 (2010-10); EN 55022:2006+A1:2007
EN 61000-3-2:2006; EN 61000-3-3:1995+A1:2000+A2:2005
EN 55024: 2010; USA FCC Class A; NEBS compliant; VCCI
Class A
FCC Part 15 Class A
VCCI Class A
ETSI EN 300 386 V1.5.1 (2010)
EN 55022:2010 Class A
EN 61000-3-2:2006 A1:2009+A2:2009
EN 61000-3-3:2008
EN 55024:2010
EN 55022:2010 Class A
EN 61000-3-2:2006 A1:2009+A2:2009
EN 61000-3-3:2008
Firewall Throughput (Packet per Second)
۲۲۰Mpps
IPS Throughput ( HTTPS / Enterprise Mix)
۶۰ / ۹۰ Gbps
Threat Protection Throughput
۳۵Gbps
SSL Inspection Throughput
۳۹.۹Gbps
Concurrent Sessions (TCP)
۱۶۰Million
Firewall Policies
۲۰۰,۰۰۰
NGFW Throughput
۵۰Gbps
Virtual Domains (Default / Maximum)
۱۰/۵۰۰
Application Control Throughput
۶۵ Gbps
Relative Humidity
۵to 85% at 104° F (40° C)
Certifications/Susceptibility Standards
EEN 300 386 V1.5.1 (2010-10); EN 55022:2006+A1:2007
EN 61000-3-2:2006; EN 61000-3-3:1995+A1:2000+A2:2005
EN 55024: 2010; USA FCC Class A; NEBS compliant; VCCI
Class A
FCC Part 15 Class A
VCCI Class A
ETSI EN 300 386 V1.5.1 (2010)
EN 55022:2010 Class A
EN 61000-3-2:2006 A1:2009+A2:2009
EN 61000-3-3:2008
EN 55024:2010
EN 55022:2010 Class A
EN 61000-3-2:2006 A1:2009+A2:2009